Add to Cart
AP-DB1217 static eliminator high speed static discharge shock-proof prevent anti static bar
Specification
Model | AP-AB1217 |
Output voltage | DC±6KV~DC±10KV |
Cord length | 2.5M(customized available) |
Power | 10W |
Power supply | AP-DC7201 |
Working distance | 30-100mm |
Ion balance | ≤|±300V|(AVE) |
Discharge time | ≤1S(working distance 100 mm) |
Working temperature | 0℃-50℃ |
Working humidity | <70% |
Features
(1)Bar shaped and cross over static eliminator.
(2)Excellent electrical property data by applying the newest static elimination technology.
(3)Suitable for high speed operating and tough rubbing material surface static discharge.
(4)Shock-proof function prevent user from being electric shocked.
(5)Stripe shaped notch on the back of the bar for user to fasten the bar.
Working way
Caution
Ion bar should be installed within the working area of static removing and installation angle should be perpendicular to the surface of the charged body
The discharge electrode of ion bar should stay away from metal conductor, metal grounding, rods must be reliable ground connected.
Trouble shooting
NO | Error | Possible reason | Solution |
1 | Power port indication LED off | Poor contact of power cord | Check status and stable connection of power cord |
Power supply mismatch | Check power supply specification(INPUT:100—240VAC 50/60Hz;OUTPUT:24VDC 1000mA) |
2 | Static removing performance decline obviously | Pollute or damage of discharge pin | Clean or replace discharge pin |
Electrode pad not tightly screwed | Be sure the electrode pad screwed tightly | ||
Improper installation position | Confirm the optimum installation position | ||
3 | Static removing performance decline | There are conductor or other ion bar around | Remove conductor or other ion bar |
4 | HV Alarm | Electromagnetic disturb | Switch off and reset |
Abnormal discharge | Check installation position and be away from conductors | ||
Pollute or damage of discharge pin | Send back to manufacture r | ||
5 | Smoking or burning | Pollute or damage of discharge pin or electrode pad insulator | Send back to manufacturer |
Contactor : Mr. Chuck
whatsapp & wechat :+86-15258707086
skype : chuck@sh-anping.com.cn