Shanghai Anping Static Technology Co.,Ltd

Shanghai Anping Static Technology Co.,Ltd

Manufacturer from China
Active Member
10 Years
Home / Products / ESD Ionizer /

Cleanroom High Voltage ESD Ionizer Suspension Static Ionizing Air Nozzle

Contact Now
Shanghai Anping Static Technology Co.,Ltd
City:shanghai
Province/State:shanghai
Country/Region:china
Contact Person:MrsJourney
Contact Now

Cleanroom High Voltage ESD Ionizer Suspension Static Ionizing Air Nozzle

Ask Latest Price
Video Channel
Brand Name :AP&T
Model Number :AP-AC2454-A
Certification :CE
Place of Origin :China
MOQ :1 pcs
Price :negotiation
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :2000 pcs / month
Delivery Time :3 to 5 working days
Packaging Details :Standard Export Packing (Carton)
Discharge Speed :≤2.0s (150mm from the front of the nozzle, the air pressure is 0.3Mpa)
Ion Balance :±50V
Power :20W
Input Voltage :220V/50HZ or 110V/60HZ
Working Voltage :AC2800V
Discharge distance :150—300mm
Wire length :2.5M (Can be customized according to requirements)
Air pressure :0.2—0.6MPa
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Cleanroom ESD Ionizer Suspension Static Ionizing Air Nozzle
Cleanroom High Voltage ESD Ionizer Suspension Static Ionizing Air Nozzle
Product description:
AP-AC2454-A ionizing air nozzle eliminates static electricity on the surface of objects. It is a fast and efficient dust removal device designed to provide electrostatic protection for the surface of the target object. .
The AP-AC2454-Aionizing air nozzle uses AC high-voltage electricity and is connected to a dedicated emitter electrode to ionize the air to generate positive and negative ions, which are transported by compressed air to the surface of the static-eliminated object and neutralize the positive and negative electrostatic charges to achieve the purpose of efficient and reliable power consumption.
Cleanroom High Voltage ESD Ionizer Suspension Static Ionizing Air Nozzle

Industry application:
Can be widely used in electronics, injection molding, printing, film and other industries.

Cleanroom High Voltage ESD Ionizer Suspension Static Ionizing Air Nozzle
Features:
1) Compact size and easy installation.
2) Excellent electrical performance index and good performance.
3) Eliminate the static electricity and remove the dust on the surface.
4)Safe and reliable to work under the condition of high voltage and micro current.
5) Configure AP-AC2455-28 special high-voltage power supply.

Product Specifications

Input voltageAC220V/50Hz or AC110V/60Hz
Working VoltageAC2800V
Discharge distance150—300mm
Power20W
Discharge speed≤2.0s (150mm from the front of the nozzle, the air pressure is 0.3Mpa)
Ion balance-50V~+50V (150mm from the front of the nozzle)
Wire length2.5M (Can be customized according to requirements)
Working temperature0—50℃
Working humidity30—70%RH
Use mediaClean compressed air
Ozone thickness<0.05ppm
Air source connectorΦ8mm
Air pressure0.2—0.6MPa
Noise<65db (150mm from the front of the nozzle, the air pressure is 0.1MPa)
Dimensions95*25*60mm(L*W*H)
Net weight400g
Gross weight480g
Supporting power supplyAP-AC2455-28


Safety warning
1. Please read the instruction manual carefully before installing and using this equipment.
2. The entire set of equipment must be reliably grounded during use, and the grounding resistance is less than 4 ohms; otherwise, the wind nozzle and high-voltage power supply may be abnormal or even damaged.
3. It is not suitable to use this equipment in the environment with >70% humidity.
4. It is strictly forbidden to use this equipment in flammable and explosive environments.
5. Unauthorized disassembly of the product is strictly prohibited, and internal maintenance and repairs must be performed by professionals.
6. The product is strictly prohibited from touching water stains, otherwise abnormality will occur, resulting in electric shock or fire.
7. When checking or replacing the product, the power must be turned off, otherwise it may cause electric shock or fire.
8. The product is specially designed to eliminate static electricity, and other uses are strictly prohibited. Any abnormal use may cause hidden troubles such as machine failure, electric shock, and fire.
9. It is strictly forbidden to touch the electrode needle when it is energized, otherwise it may cause malfunction and electric shock accident.
10. The discharge needle is a sharp metal object, please use it carefully.
11. Before the product is powered on, please check the specifications of the power supply. Any power supply that does not meet the specifications will cause damage or even failure to the product.
12. Please check the power cord of the product regularly, and replace it if it is damaged, otherwise it may cause problems such as leakage and abnormal work.
13. When using the air nozzle, an air purification filter device should be installed at the air source interface to ensure that the gas entering the air nozzle body is dry and clean, so as to prevent the water vapor and grease in the air source from entering the nozzle part of the air nozzle to cause a high voltage short circuit and affect Normal use.

Installation
1. Installation steps:
1) Reasonably set the best power dissipation position of the air nozzle, and install it firmly.
2) Insert the φ8 compressed air tube into the air nozzle of the air nozzle.
3) Connect the high-voltage connection wire and ground wire of the air nozzle to the high-voltage power supply.
4) Insert the national standard power cord plug into the socket of the high-voltage power supply.
5) Turn on the high-voltage power switch, the indicator light shows work.








































Inquiry Cart 0