Brand Name :AP&T
Model Number :AP-DC2453
Certification :CE
Place of Origin :China
MOQ :1pcs
Price :negotiation
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :2000 pcs / month
Delivery Time :3 to 5 working days
Packaging Details :Standard Export Packing (Carton)
Discharge Speed :<1.5s
Ion Balance :±10V
Power :5.5W
Input Voltage :220V/50HZ or 110V/60HZ
Working Voltage :±DC4000-DC7000V
Dimension :18086*65*202mm
Ion emission :Steady DC
Emitter electrode :Tungsten alloy
Discharge structure :Uncoupled electrical contact (discharge cylinder)
Discharge range :450*300mm(L*W)
Air volume :≤48.2CFM
Noise :≤38.9db (1m away from the air outlet)
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

AP-DC2453 Mini DC Ionizing Air Blower Hanging ESD Ionizer For Optoelectronics Industry

Product description

AP-DC2453 mini ionizing air blower is one of ionizing air blower series products produced by Anping Company (AP & T).

The AP-DC2453 mini ionizing air blower uses positive and negative synchronous emission electrodes to generate corona discharge through DC high voltage, ionizing air molecules, generating a large number of positive and negative air ions and blowing them to the surface of the object to be eliminated by an axial fan Perform static elimination.

AP-DC2453 Mini DC Ionizing Air Blower Hanging ESD Ionizer For Optoelectronics Industry

Industry application

Can be widely used in electronics, optoelectronics, semiconductors and other industries.

Product Features

1) Compact size and easy installation.

2) Can be installed inside the device to eliminate static electricity.

3) Low power and long service life.

4) The circuit performance is stable, safe and reliable.

5) The wind speed can be adjusted in three levels: high, medium and low.

6) The front and rear net covers are removable, which is convenient for cleaning and maintenance.

7) Configure a dedicated external power adapter.

AP-DC2453 Mini DC Ionizing Air Blower Hanging ESD Ionizer For Optoelectronics Industry

Specification

Model AP-DC2453
Input voltage DC12V
Power 5.5W
Working Voltage ±DC4000-DC7000V
Ion emission Steady DC
Emitter electrode Tungsten alloy
Discharge structure Uncoupled electrical contact (discharge cylinder)
Discharge range 450*300mm(L*W)
Discharge speed ≤1.5s (150mm from the front of the air outlet)
Ion balance -15V ~ + 15V (150mm from the front of the air outlet)
Alarm indication The power indicator is on and working normally
Air volume ≤48.2CFM
Noise ≤38.9db (1m away from the air outlet)
Ozone thickness ≤0.05ppm (150mm away from the air outlet)
Working temperature 0-50℃
Working humidity 30-70%RH
Dimensions 113*54*129mm(L*W*H)
Shell material Aluminum dusting
Installation accessories

1 pair of U-shaped aluminum powder spraying mounting brackets,

1 pair of bakelite screw handles (M5 × 10)

Adapter power INPUT: AC100-240V 50/60Hz;OUTPUT: DC12V 1000mA
Net weight 350g (blower body, including mounting bracket and screw handle)
Gross weight 600g
Warranty 1 year
Shipping Air,Railway,Ship etc

AP-DC2453 Mini DC Ionizing Air Blower Hanging ESD Ionizer For Optoelectronics Industry

Safety Warning

1. Please read the instruction manual carefully before installing and using this equipment.

2. It is not suitable to use this equipment in the environment with> 70% humidity.

3. It is strictly forbidden to use this equipment in flammable and explosive environments.

4. Unauthorized disassembly of the product is strictly prohibited, and internal maintenance and repairs must be performed by professionals.

5. The product is strictly prohibited from touching water stains, otherwise an abnormality may occur, resulting in electric shock or fire.

6. Check or replace the product, you must turn off the power, otherwise it may cause electric shock or fire.

7. The product is specially designed for removing static electricity. Other uses are strictly prohibited. Any abnormal use may cause hidden troubles such as machine failure, electric shock and fire.

8. It is strictly forbidden to touch the electrode needle when it is energized, otherwise it may cause malfunction and electric shock accident.

9. The discharge needle is a sharp metal object, please use it carefully.

10. Before the product is powered on, please check the specifications of the power supply. Any power supply that does not meet the specifications will cause damage or even failure to the product.

11. Please check the power cord of the product regularly. If it is damaged, please replace it immediately, otherwise it may cause problems such as leakage and abnormal work.

The air inlet is at least 15cm away from the wall.

1) Failure solution:

NO. Problems Possible reason Solution
1 Fan panel indicator does not light Poor power connection Confirm whether the power supply is intact and the connection is firm
Power supply mismatch Confirm the specifications of the adapter power supply (INPUT: 100-240VAC 50 / 60Hz; OUTPUT: 12VDC 1000mA)
2 Discharge performance is significantly reduced Discharge needle pollution and damage Clean or replace the discharge needle
Improper setting of ion fan Confirm the best installation location
3 Reduced discharge performance There are conductors or other ion fans around the ion fan Remove (moving) conductors or other ion fans
5 Can't discharge High voltage module damaged Return to factory for repair
The motherboard chip is damaged Return to factory for repair
6 Product smoke or burn Main control board components burned Return to factory for repair

Maintenance

1. In order to ensure the good performance of the product, ionizing air blower should be cleaned and maintained in time according to the use environment and the required electrostatic protection requirements, that is: gently clean with an electrostatic brush, a clean cotton swab, a clean cloth dipped in anhydrous alcohol Carbon deposits on the discharge electrode and the metal mesh cover. Note:

A. It must be operated 10 minutes after the power is turned off.

B. During the use of the fan, when the needle tip has dust or white products, it must be cleaned.

C. After cleaning, you must wait for the alcohol to completely volatilize before powering on. Do not use any other organic solvents to clean the fan.

D. The alloy electrode is a consumable item, which is not covered by the warranty. The company must charge a replacement for maintenance.

2. Each control on the fan panel is pressed by the knob. The user must not press or rotate with excessive force, otherwise, the device will be permanently damaged.

3. If the power indicator on the front panel of the fan is off, it should be stopped and checked and repaired by professional maintenance personnel. It can be used only after the electrical performance index is normal.

China AP-DC2453 Mini DC Ionizing Air Blower Hanging ESD Ionizer For Optoelectronics Industry for sale

AP-DC2453 Mini DC Ionizing Air Blower Hanging ESD Ionizer For Optoelectronics Industry

Inquiry Cart 0